Effects of hydraulic loading rate on pollutants removal by a deep subsurface wastewater infiltration system

Ying-Hua Li,Hai-Bo Li,Tie-Heng Sun,Xin Wang
DOI: https://doi.org/10.1016/j.ecoleng.2011.03.029
IF: 3.8
2011-01-01
Ecological Engineering
Abstract:The subsurface wastewater infiltration (SWI) system proved to be an effective and low-cost technique for decentralized sewage treatment in areas without adequate domestic treatment facilities. Field-scale experiments were conducted through a deep SWI system, with effective depth of 1.5m, under hydraulic loading rates of 0.040, 0.065, 0.081 and 0.10m3/m2d. Taking the hydraulic and treatment efficiencies into consideration, the hydraulic loading rate of 0.081m3/m2d was recommended. Under this condition, NH3–N, TN, and COD removal efficiencies were 86.2±3.0, 80.7±1.9 and 84.8±2.1%, respectively. In the effluent, NH3–N concentration declined to 2.3–4.4mg/L, accounting for 63.2–65.6% of TN. NO3–N concentration increased from 0.2 to 0.3mg/L in the influent to 2.0–2.5mg/L in the effluent. The nitrifying bacteria number declined with increased depth, while the amount of denitrifying bacteria increased. The analysis of results about the nitrifying and denitrifying bacteria distribution indicated that the most effective ranges for nitrification and denitrification process were 0.3–0.7m and 0.7–1.5m, respectively.
What problem does this paper attempt to address?