Improved Gamma Bang Time Measurements on Omega

H. W. Herrmann,S. E. Caldwell,D. Drew,S. C. Evans,V. Yu Glebov,C. J. Horsfield,J. M. Mack,G. S. Macrum,E. K. Miller,P. Sanchez,T. Sedillo,C. Stoeckl,D. C. Wilson,C. S. Young
DOI: https://doi.org/10.1088/1742-6596/112/3/032084
2006-01-01
Abstract:The time of peak fusion reactivity with respect to the impingement of laser light on an Inertial Confinement Fusion (ICF) capsule is known as Bang Time (BT). For deuterium-tritium fueling, fusion reactivity and BT can be measured using either fusion neutrons or fusion gammas. Initial gamma bang time (GBT) measurements on Omega using a Gas Cherenkov Detector (GCD) have been previously reported [1]. Recent improvements have significantly enhanced the ability to measure GBT precisely. By relating the peak of the GCD gamma signal to laser timing fiducials, and cross calibrating the resulting raw bang time to the neutron bang time obtained using the absolutely calibrated Neutron Temporal Diagnostic (NTD), we demonstrate a precision of better than 25 ps on Omega. Bang time, along with other aspects of reaction history (RH), is an essential component of diagnosing failed attempts at ICF ignition. For the NIF, gammas are preferred over neutrons for this application due to the unacceptably large neutron temporal spreading resulting from detector standoff limitations on the NIF. The NIF System Design Requirement specifies a gamma bang time accuracy of better than 50 ps.
What problem does this paper attempt to address?