Measurement of Areal Density in the Ablators of Inertial-Confinement-fusion Capsules Via Detection of Ablator (n, N′γ) Gamma-Ray Emission

N. M. Hoffman,H. W. Herrmann,Y. H. Kim,H. H. Hsu,C. J. Horsfield,M. S. Rubery,E. K. Miller,E. Grafil,W. Stoeffl,J. A. Church,C. S. Young,J. M. Mack,D. C. Wilson,J. R. Langenbrunner,S. C. Evans,T. J. Sedillo,V. Yu. Glebov,T. Duffy
DOI: https://doi.org/10.1063/1.4799799
IF: 2.2
2013-01-01
Physics of Plasmas
Abstract:We report the first gamma-ray-based measurements of the areal density of ablators in inertial-confinement-fusion capsule implosions. The measurements, made at the OMEGA laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], used observations of gamma rays arising from inelastic scattering of 14.1-MeV deuterium-tritium (DT) neutrons on 12C nuclei in the compressed plastic ablators. The emission of 12C(n,n′γ) gamma rays from the capsules is detected using the Gamma Reaction History instrument [H. W. Herrmann et al., J. Phys.: Conf. Ser. 244, 032047 (2010)] operating at OMEGA. From the ratio of a capsule's 12C(n,n′γ) emission to the emission from the same processes in an in situ reference graphite “puck” of known mass and geometry [N. M. Hoffman et al., in IFSA 2011 proceedings (submitted)], we determine the time-averaged areal density of 12C in the capsule's compressed ablator. Measured values of total ablator areal density for thirteen imploded capsules, in the range 23 ± 10 to 58 ± 14 mg/cm2, are comparable to values calculated in 1D radiation-hydrodynamic simulations, and measured by charged-particle techniques.
What problem does this paper attempt to address?