Effect of Different Definition for Lung Volume on the Radiation Dosimetry for Lung Cancer

LI Jian-cheng,CHEN Cheng,PAN Jian-ji
2013-01-01
Abstract:[Purpose] To investigate the effect of different definition for lung volume on the radiation dosimetry for lung cancer. [Methods] Twenty patients with lung cancer were treated with intensity modulated radiation therapy,and the GTV,CTV,PTV of primary tumor and organs at risk were delineated. Normal lung volumes with different definitions were divided into four groups ,and the differences of V 20 ,V 5 and MLD were analyzed by paired t-test. [Results] The parameters varied considerably with different definitions of lung volume and the rangeability positively correlated with GTV ,especially the V 20 . When GTV/lung volume represented the GTV,the effect of GTV on the lung dosimetric parameters would be better presented.[Conclusion] Different definitions of lung volume have an effect on the lung dosimetric parameters.
What problem does this paper attempt to address?