Calibration Circuit for TOF Read-out Electronics of BESⅢ

FENG Changqing,LIU Shubin,HUANG Yaqi,AN Qi
2010-01-01
Nuclear Techniques
Abstract:A calibration circuit for BESIII TOF electronics is described in this paper.An exponential-decay calibrating signal,of which the charge(integrated area of amplitude) was set by remotely-controlled DAC via VME bus,was generated by fast analog switch and fed to each time-and-charge measurement channel of TOF readout electronics.It has the charge accuracy of better than 10 bits and the dynamic range of more than 20 times.Detailed tests suggest that the nonlinearity of charge measurement,normally about 2%,can be greatly reduced to less than 0.6% after calibration.This calibration circuit scheme has been applied in BESIII project successfully.
What problem does this paper attempt to address?