Test of Loading Capacity for Glass Curtain Wall with an Invisible Single Cable

WANG Yuanqing,XU Kang,WANG Deqin,SHI Yongjiu,Ken Y LUO
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.09.006
2009-01-01
Abstract:The influences of the cable pre-stress,glass rigidity,sealant,and sleeve on the loading capacity of a glass curtain wall supported by an invisible single cable were studied experimentally.The loading capacity was measured after each step of pre-stressing,glass installation,load application,injection of sealant,and placement of sleeve.The natural frequencies were also measured for various pre-stresses,glass rigidity,and glass masses.The results show that higher pre-pressing can support larger loads with less deflection reduction.The glass mass has a larger influence on the natural frequency than the glass rigidity,while the sealant and sleeve have little effect on the loading capacity.
What problem does this paper attempt to address?