Seismic analysis method for point-supported glass curtain wall with single-layer cable net

Shi Yongjiu,Li Yong,Wang Yuanqing
2010-01-01
Abstract:Due to the influence of geometric nonlinearity of cable net and the second input from the primary structures,seismic analysis for point-supported glass curtain wall with single-layer cable net is more complex.While the current design codes rarely take these effects into account with simple equivalent static method,in which the seismic coefficient is taken as the peak value of linear structures.And it is also unrealistic by ignoring the influence of primary structure.Based on the mode participation properties of cable net under earthquake,it suggests that the first mode is predominant.Combined with the characteristic of even distribution of mass and stiffness of cable net,modified equivalent static method was proposed with validity after comparison with other methods.As for the nonlinear seismic influence coefficient,it can be obtained from the equivalent single-degree-of-freedom with the same linear period and geometric nonlinearity factor.The influence of primary structure can be taken into account with its dynamic influence factor,which varies from the ratio of basic frequency between primary structure and cable net.
What problem does this paper attempt to address?