ANALYSIS OF GAS CONCENTRATION AND IMPINGING FLAME HEIGHT IN THE ENTRAINED-FLOW GASIFIER

Zhang Zhiwen,Guo Qinghua,Yu Guangsuo,Yu Zunhong,Dai Songtao,Li Xinglong
DOI: https://doi.org/10.3969/j.issn.1004-4248.2008.01.007
2008-01-01
Abstract:In a bench-scale installation of four-burner impinging entrained-flow gasifier,detailed measurements of gas concentration distribution have been performed for diesel oil at atmospheric pressure.Gas samples of different radial positions in the burner plane and different axial positions up the burner plane were cleaned through gas purified system which then analyzed by mass spectrometry.Results showed that the concentration of CO,CO2,H2 changed relatively fiercely until 5 cm offside the gasifier center,which was called the flame impinging region.The place of the inflexion point in the gas concentration curve indicates that the flame height is nearly 30 cm,so the ratio of flame height to the gasifier diameter is about 1.0.
What problem does this paper attempt to address?