Study of Pharmacokinetics and Bioequivalence of Rosuvastatin Capsules by High Performance Liquid Chromatographic-Mass Spectrometry

ZHANG Hong,LIANG Chao,CHENG Xiao-hua,CHEN Yue-jiang,LI Yan-yan,XIONG Yu-qing
DOI: https://doi.org/10.3969/j.issn.1007-7669.2006.12.007
2006-01-01
Abstract:AIM: To study the pharmacokinetics and bioequivalence of rosuvastatin capsules in healthy people. METHODS: Twenty healthy male volunteers were enrolled into the single crossover study. A single dose of the suspension equivalent to rosuvastatin 10 mg or a reference preparation was given crossoverly to each of the individual, respectively. A sensitive and specific high performance liquid chromatography-mass spectro-metric method (HPLC-MS) was used for the determination of rosuvastatin concentration in human plasma, and the bioequivalences of the suspension and the reference were evaluated by pharmacokinetic parameters and relative bioavailability obtained. RESULTS: The pharmacokinetic parameters for rosuvastatin and reference preparation were: cmax(12±4) vs (11±4)μg·L-1, AUC0-72(123±47) vs (123±42)μg·h·L-1, tmax(3.3±0.9) vs (3.4±1.0) h, t1/2 (18±7) vs (18±5) h, respectively. The linear correlative range was well within the con- centration 0.1~20.0μg·L-1. The lowest detectable concentration of rosuvastatin was 0.1μg·L-1, with no significant difference in pharmacokinetic parameters. CONCLUSION: HPLC-MS merits for good sensitivity, accuracy, and simplicity, suitable for studing the pharmacokenitics and bioequivalent of rosuvastatin.
What problem does this paper attempt to address?