Load-carrying capacity of 550MPa high-strength cold-formed thin-walled steel built-up box section columns

Li Yuanqi,Yao Xingyou,Shen Zuyan,Wang Shukun,Liu Xiang
2011-01-01
Abstract:Built-up box section columns by two lipped channel sections are widely used in super thin-walled cold-formed steel structures.However,for their load-carrying capacities of built-up box section columns,usually a mathematical sum according to the load-carrying capacities of each channel section involved is utilized without any further consideration on the reinforcement between single channel sections.Load-carrying capacities and failure modes of 40 high-strength cold-formed thin-walled steel built-up box section columns have been studied,including 21 axially-compressed columns and 19 eccentrically-compressed columns subjected to bending moments along the weak axis and the strong axis respectively.The results show that,due to the interaction between two lipped channel columns connected by self-drilling screws,the ultimate load-carrying capacity of a built-up box section column is 10% to 20% higher than the sum of the ultimate load-carrying capacity of two single lipped channels loaded in the same way independently.Based on the tests and theoretical analysis,a proposed method to estimate the ultimate load-carrying capacity of built-up box section columns reasonably was presented.It can give a close and conservative estimation results,and be referred in practical design.