Separation characteristics of human epidermal growth factor in ion exchange chromatography with STREAMLINE DEAE resin

Wang-Yu Tong,Shan-Jing Yao,Zi-Qiang Zhu
DOI: https://doi.org/10.1016/S0009-2509(01)00328-1
IF: 4.7
2001-01-01
Chemical Engineering Science
Abstract:Human epidermal growth factor (hEGF), a polypeptide hormone comprised of 53 amino acid residues, is progressively displaying its importance in medicine and cosmetic fields. In order to purify hEGF, the influences of different linear flow rates, sample volumes injected, column bed heights, gradient lengths of NaCl concentration, pHs and sample concentrations on the separation of hEGF in ion exchange chromatography with STREAMLINE DEAE were investigated. Under the partial optimal conditions of the linear flow rate of 150cm/h, the sample volume injected of 50ml, the column bed height of 11.3cm, the gradient length of 2 column volume (2MNaCl) and the pH 7.0, a crude product of hEGF was obtained from the fermentation supernatant through centrifugation at 8000 rpm for 30min on an ÄKTA explorer 100 using a XK 16/20 column containing STREAMLINE DEAE resin. The content of hEGF in the crude product is more than 10% and the yield of recovery is higher than 85%, respectively. In addition, the values of the retention volume of hEGF under the given conditions were determined.