Simulation on the Kinetics for Cr/H/Air Incineration System

LV Xue-Feng,YU Su-yuan,CHEN Long
DOI: https://doi.org/10.3969/j.issn.1007-2691.2012.03.017
2011-01-01
Abstract:A primary Cr/H/Air reaction kinetic model is studied by Gaussian 03 code with quantum chemistry theory.Then,the kinetic model is corrected,five overall reactions are omitted from and seven elementary reactions are added in the model.Numerical results show that the hexavalent chromium compound CrO2(OH)2 appears from 1 000 K to 2 200 K,and reached its peak at about 1 700 K.Therefore,it is suggested that the practical industrial incineration avoid the temperature area around 1 700 K to reduce the production of hexavalent chromium.
What problem does this paper attempt to address?