Comparative Study of Bipolar Electrocoagulation and Traditional Ligation Used in Thyroidectomy

LI Wen-xiu,JIN Xiao-jie,LI Ji-ping,FU Wei,ZHOU Jia-qing,ZHANG Yi,LUO Hua-jie,ZHOU Qin-yi,LIU Jun,QIAN Min-fei,LIU Rong-yao,ZHOU Ming
2009-01-01
Abstract:OBJECTIVE To study the feasibility of bipolar electrocoagulation substituting traditional ligation for hemostasis in thyroid operation.METHODS 78 patients underwent near total thyroidectomy and total thyroidectomy.In 38 patients bipolar electrocoagulation was used for hemostasis and in the other 40 patients ligation was used to treat broken vessels.The bleeding quantity in operation,the drainage of the first day after operation and the operation duration both groups were compared. RESULTS There was no significant difference in bleeding quantity between these 2 groups.The quantity of drainage was less in patients used bipolar electrocoagulation.The average bleeding quantity was (54±14) ml in bipolar electrocoagulation group,and (63±10) ml in ligation group.There was no significant difference between these 2 groups.The drainage of the first day after operation was statistically less in bipolar electrocoagulation group(P0.05).One patient with thyroid papillary carcinoma in ligation group suffered recurrent laryngeal nerve paralysis after operation. There was no hypoparathyroidism in these 2 groups. CONCLUSION Using bipolar electrocoagulation the formation of foreign body from ligation may be avoided and local anesthesia in thyroid operation may also allowed,which could help to reduce the operation fee.
What problem does this paper attempt to address?