Cloud point extraction for high-performance liquid chromatographic speciation of Cr(III) and Cr(VI) in aqueous solutions.

An-Na Tang,Dong-Qing Jiang,Yan Jiang,Shan-Wei Wang,Xiu-Ping Yan
DOI: https://doi.org/10.1016/j.chroma.2004.02.065
IF: 4.601
2004-01-01
Journal of Chromatography A
Abstract:Cloud point extraction (CPE) was applied as a preconcentration step for HPLC speciation of chromium in aqueous solutions. Simultanous preconcentration of Cr(III) and Cr(VI) in aqueous solutions was achieved by CPE with diethyldithiocarbamate (DDTC) as the chelating agent and Triton X-114 as the extractant. Baseline separation of the DDTC chelates of Cr(III) and Cr(VI) was realized on a RP-C18 column with the use of a mixture of methanol–water–acetonitrile (65:21:14, v/v) buffered with 0.05M NaAc–HAc solution (pH 3.6) as the mobile phase at a flow rate of 1.0mlmin−1. The precision (R.S.D.) for eight replicate injections of a mixture of 100μgl−1 of Cr(III) and Cr(VI) were 0.6 and 0.5% for the retention time, 4.1 and 4.6% for the peak area measurement, respectively. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for HPLC separation and in the initial solution, was 65 for Cr(III) and 19 for Cr(VI). The linear concentration range was from 50 to 1000μgl−1 for Cr(III) and 50–2000μgl−1 for Cr(VI). The detection limits of Cr(III) and Cr(VI) were 3.4 and 5.2μgl−1, respectively. The developed method was applied to the speciation of Cr(III) and Cr(VI) in snow water, river water, seawater and wastewater samples.
What problem does this paper attempt to address?