Abstract:Objective:To summarize the experience of single-site transumbilical laparoscopic surgery for kidney and ureter disease and explore its feasibility.Methods:From Aug.2009 to Jan.2010,with self-made multi-channel single-port equipment,6 cases of non-functioning kidney patients and 12 cases of ureteral calculi patients underwent laparoscopic single-site transumbilical surgery.2cm peri-umbilical incision was made,self-made multi-channel single-port equipment,common laparoscopic equipment and flexible operating equipments were inserted into the abdominal cavity and specimens was removed from the umbilical incision.Results:Seventeen laparoscopic single-port operations were completed successfully.The mean operative time was(123.3±23.4)min,mean blood loss was(86.5±12.4)ml.1 case with abdominal aortic injury was converted to open surgery.The mean postoperative hospital stay was 7d,mean duration of drainage catheter was 3.5d,the patients were followed up 2-14 months,during which no complications occurred.Conclusions:The laparoscopic single-site transumbilical surgery for upper urinary tract lesions is safe and feasible,scar hidden,has good cosmetic results and can be a new clinical treatment method.