HPLC Determination of Acetate in Dialysate

柯林楠,母瑞红,冯晓明,奚廷斐
2009-01-01
Abstract:Objective:To introduce a determination method of acetate in dialysate.Method:High liquid chromatography(HPLC)was used to determine acetate.A under the chromatographic conditions:Rezex ROA-Organic Acid H+(150 mm×7.8 mm,8 μm)column;mobile phase was 0.0025 mol·L-1 sulfuric acid solution at a flow rate of 0.5 mL·min-1,detection wavelength was 220 nm.Results:The linear correlation of acetate was 1.64-6.54 mmol·L-1 with correlation coefficient of 0.9994.The average recovery was 100.6%,RSD=0.08%(n=5).Conclusions:The results showed that the method is accurate,simple and rapid for analysis of acetate in dialysate.