Abstract:The newly developed 4PPa-2PaR parallel mechanism has subchains on its limbs, and the imperfect assembly process causes the kinematic error. The conventional matrix-based method is difficult to set up its kinematic error model, as the kinematic constraints cannot be represented by the homogenous transformation matrix intuitively. In this work, the actual kinematic model is established using a vector-based method, considering the nonideal lengths of links and misalignment of active joints’ home sensors. Thereby, the kinematic constraints of the mechanism are intuitively incorporated into the model, and the deviations of kinematic parameters are identified by the Levenberg–Marquardt algorithm. To achieve error compensation using the inverse of the actual kinematic model, a flange with three collinear reflector holders is designed and mounted on the moving platform, and a three-point measurement method is utilized to capture its pose without using a tracker-machine control sensor (T-MAC). Another flange for reflector holders is designed and mounted on the active joint for setting up the base frame so that all measurement data are transformed from the laser tracker’s frame to the base frame to complete the calibration process. Experiments are conducted on the testbed to validate the effectiveness of the proposed calibration method.