An Improved Method for the Error Modeling of a 5-DoF Parallel Machining Robot Based on Measurement by a Laser Tracker

Xuan Luo,Fugui Xie,Xin-Jun Liu,Zenghui Xie,Zaihua Yang
DOI: https://doi.org/10.1109/CYBER46603.2019.9066693
2019-01-01
Abstract:Kinematic calibration of 5-DoF parallel robots is very challenging, due to the difficulty in accomplishing the efficient and precise measurement of the end-effector's pose errors, and the situation that the terms of the error mapping Jacobian matrix (EMJM) in various units will restrict the identification accuracy. This paper proposes an improved error modeling method based on measurement by a laser tracker to deal with these problems for a 5-DoF parallel machining robot, DiaRoM-II. Two steps of modeling modification are developed as: (1) reselecting the robot's geometric errors in a uniform unit; (2) substituting the pose errors of the end-effector with the position errors of two points along the axis of the spindle. Accordingly, the dimensionless EMJM is established. On this basis, the identification simulation experiments are conducted, and the results verify that the improved error modeling method is effective in accurately identifying the geometric errors of DiaRoM-II.
What problem does this paper attempt to address?