Preliminary Study on Radiological Protection level of Nuclear Medicine Department of A Hospital

LI Chang-hong,LIU De-ming,ZHU Jun
2009-01-01
Abstract:[Objective]To analyze the test results of radiological protection level of nuclear medicine department of a hospital,so as to put forward optimized suggestion for radiological protection.[Methods]According to relative national standards,"FD-3013B" intelligent γradiometer was applied to measure the level of environmental radiological protection in nuclear medicine workplace,and "FJ-2201"(α、β) Surface contamination meter was used to conduct detection of surface contamination.[Results]The radiation maximum of the department and the surroundings was 1.95 μSv/h,the maximum of environmental radiation dose rate was 2.04 μSv/h,the maximum of surface contamination was0.29 Bq/cm2,the annually maximum effective dose among professional staff was 2.1 mSv.[Conclusion]The site of the nuclear medicine department is appropriate,and the layout is rational.The monitoring results for the radio protection and surface contamination in workplace accord with national standards.To protect the health of the staff and the public,the detection for the radio protection in all workplaces should be strengthened to realize the legitimacy of the practice and the optimization for the medical radiation.