Modeling and Dynamic Analysis of the Mass Flow Control System Used for Rocket Engine

TAO Yu-jing,TIAN Zhang-fu,WANG Zhen-guo
DOI: https://doi.org/10.3969/j.issn.1673-9728.2006.02.187
2006-01-01
Abstract:Variable throat venture for cryogenic propellants was the key component for the mass flow control system. And Stcp motor was used to control the displace of the tapered rod.This paper studied the adjust-speed and adjust-pre- cision of the step motor by establishing the dynamic models of it.The mass flow at cavitation was maximal as the geo- metric structure of Venturi was fixed,which could judge if Venturi was cavitated.Based on this fact,uniform dynamic models of throttling Venturi were established when Venturi was cavitated or not.The mass flow control system was simulated,and the comparison with the test results showed the models were correct.This paper also studied the ability to against the fluctuation of back pressure and to control the mass flow by the dynamic models.