Influence of User Room Location in Residential Building on Metered Heat

Yan SUN,Huan ZHANG,Yu-chen TIAN,Ke-rong CUI
DOI: https://doi.org/10.3969/j.issn.1000-4416.2007.07.021
2007-01-01
Abstract:Through the comparative analysis of the acquired data from 2006 to 2007 in a metered heating residential area,the location heat consumption ratio coefficient that reflects the influence of user room locations on their metered heat is calculated.The better the thermal insulation performance of building envelop,the smaller the difference of the location heat consumption ratio coefficient of user rooms with different locations is.After adding the influencing factor of user regulation of indoor temperature,the difference of the location heat consumption ratio coefficient of user rooms with different locations becomes small.The variation of outdoor temperature has little effect on the location heat consumption ratio coefficient of user rooms with different locations.