Pretreatment of pyrimidine wastewater by aerated micro-electrolysis and flocculation technique

WANG Li-juan,LIN Nian-feng,HUANG Ji-guo,LV Zhen
DOI: https://doi.org/10.13229/j.cnki.jdxbgxb2008.06.012
2008-01-01
Abstract:The technique of aerated micro-electrolysis and flocculation was employed to process high concentrated pyrimidine wastewater.The effects of the pH value of influent water,Hydraulic Retention Time(HRT),aeration intensity,temperature and flocculation type on the removal rate of COD were investigated.Results show that,when the COD concentration in the influent water is 484568 mg/L,the optimal processing parameters of the aerated micro-electrolysis are pH value 3 of the influent water,HRT 4.7 h,aeration intensity 88.2 m3/(m2·h),temperature 30 ℃.Under such condition,the COD removal rate was over 70%,the B/C value was increased from 0.09 to about 0.32,and the biodegradable capability was greatly increased.
What problem does this paper attempt to address?