Experimental Study on Demercurization Performance of Wet Flue Gas Desulfurization System

Bao Jingjing,Yang Linjun,Yan Jinpei
DOI: https://doi.org/10.1002/cjoc.200990376
IF: 5.56
2009-01-01
Chinese Journal of Chemistry
Abstract:The demercurization performance of wet flue gas desulfurization (WFGD) system was investigated by measuring mercury concentrations at the inlet and Outlet of WFGD system with a QM201H mercury analyzer The selected desulfurizer included NH3 center dot H2O, NaOH, Na2Co3, Ca(OH)(2) and CaCO3. The influences of adding oxidant and coagulant such as KMnO4. Fenton reagent, K2S2O8/CuSO4 and Na2S into desulfurization solutions were also studied. The results show that elemental mercury is the main component of gaseous mercury in coal-fired flue gas, and the proportion of oxidized mercury is leas than 36% Oxidized mercury Could be removed by WFGD system efficiently. and the removal efficiency could amount to 81.1%-92.6% However, the concentration of elemental mercury slightly increased at the outlet of WFGD as a result of its insolubility and re-emission Therefore, the removal efficiency of gaseous merctuy is only 13.3%-183%. The mercury removal efficiency of WFGD system increased with increasing the liquid-gas ratio. In addition, adding KMnO4, Fenton reagent, K2S2O8/CuSO4 and Na2S into desulfurization solutions could increase the mercury removal efficiency obviously. Various additives have different effects, and Na2S is demonstrated to be the most efficient, in which a niercury removal efficiency of 67.2% can be reached.
What problem does this paper attempt to address?