Analysis on unsteady frosting rate for air-heated finned-tube vaporizer

Chen Shuping,Xie Fushou,Yao Shuting,Han Hongyin,Chang Zhixin
DOI: https://doi.org/10.3969/j.issn.1001-7100.2013.03.001
2013-01-01
Abstract:The flow state of moist air near air-heated finned tuber vaporizer was observed at an actual operating liquid argon station.Based on thermodynamic theory and flow state of moist air,the surface frost model of air-heated finned-tube vaporizer was established.The calculation formulas of unsteady frosting rate were derived,and some influencing factors of unsteady frosting rate were analyzed.The result shows unsteady frosting rate is continuously increasing with temperature,relative humidity and gas velocity.The temperature and relative humidity of moist air are main factors affecting frost accumulation,while the effect of gas velocity is relatively small.The analysis on unsteady frosting rate will provide a theory basis for exactly calculating the heat transfer of air-heated finned-tube vaporizer in the engineering application.
What problem does this paper attempt to address?