Transesophageal echocardiography detecteting venous air embolism in pigs: experimental study

ZHANG Wei-xing,HU Bing,WANG Ai-zhong,ZHOU Ming,XUE Xiao-pei
DOI: https://doi.org/10.3969/j.issn.1672-6448.2006.06.003
2006-01-01
Abstract:ObjectiveTo monitor the manifestation of venous air embolism through jugular vein into pig's heart chamber using transesophageal echocardiography (TEE), and to obtain lethal dose of venous air embolism in pigs. MethodsSix pigs were injected with air from 0.05-4 ml/kg via the internal jugular vein. These pigs were continuously monitored with TEE. Lethal dosage of air embolism in each pig was recorded. ResultsAlong with the increase of injected air , high echogenic particles found in the right heart were moving continuously , aggregated and disappeared gradually. The emptying time varied from 15 seconds to 40 minutes. Paradoxical air embolism occurred in one of the six pigs .The accumulated lethal dose of air embolism was 276-667 ml in different pigs. ConclusionsAir emboli in the heart chamber could be detected sensitively with TEE, and the average accumulated lethal dose of air embolism was 397±105 ml in pigs.
What problem does this paper attempt to address?