Correlative study of augmentation index (AI) and parameters of pulse presentations

徐芳,肖沪生,徐智章,张爱宏,彭欣,银浩强,陆盈,高东雯,朱蓓菁,俞成杰,雍丽
2010-01-01
Abstract:Objective To investigate the correlation of Augmentation Index(AI) and pulse presentations related parameters and its clinical significance.Methods 53 cases of healthy people were included.The AI of carotid artery was detected with Prosoundα10 color Doppler ultrasonograph made in ALOCK company.And the pulse presentations time domain analysis parameters of radial artery were detected with DDMX—100 pulsography.The correlation of the both sides was researched.Results There were positive correlations between AI and h_3/h_1(r=0.670,P<0.01),between AI and h_4/h_1(r=0.579,P<0.01),between AI and h_4(r=0.364,P<0.01),between AI and t(r=0.351,P<0.05).There were negative correlations between AI and h_5(r=-0.592,P<0.01),between AI and h_5/h_1(r=-0.596,P<0.01), between AI and h_1/t_1(r=-0.350,P<0.05 ).There were no correlations between AI and h_1,t_1,t_5,t_5/t_4,As and Ad.Conclusion As one of the classic indexes,AI is helpful to screen indexes reflecting arterial elasticity in multiple parameters of pulse presentations.