Particle Image Velocimetry(piv) Measurements of the Flow in a Rotating Cavity with a Radial Inflow

Xiao YU,Xiang LUO,Guo-qing XU,Ji-ning SUN
DOI: https://doi.org/10.13224/j.cnki.jasp.2009.11.029
2009-01-01
Abstract:Particle image velocimetry (PIV) was applied to a multifunctional rotating facility, the velocity distributions in the rotating cavity with a radial inflow of fluid had been measured in different working conditions. The experimental facility, experimental method and error analysis were introduced. The instantaneous and ensemble-average velocity fields in the rotating cavity had been discussed in this paper. And the results show PIV can be used to analyze the velocity field in a complex rotating cavity and the influence of non-dimensional mass flow-rate and rotating Reynolds number. At the same time, the light reflection control and the symmetrical and steady dispersion of tracer particles are the key factors of the PIV measurement.
What problem does this paper attempt to address?