Treatment of Wastewater Containing RDX by Fenton's Reagent

XU Hang,ZHANG Dong-xiang,XU Wen-guo,徐航,张东翔,徐文国
2008-01-01
Abstract:Fenton's reagent was employed to treat the wastewater containing RDX.The effects of FeSO4 concentration,H2O2 concentration,pH value,reaction time,temperature and initial COD of wastewater on residual COD of wastewater were investigated.The results show that the optimum FeSO4 concentration and pH are 700 mg/L and 2.5,respectively,and the residual COD of wastewater decreases with the rise in H2O2 concentration,but increases with the rise in temperature.After Fenton's reagent treatment,the initial COD of less than 874 mg/L wastewater can meet effluent standard.Under conditions of 100 mg/L H2O2,437 mg/L initial COD and 15 ℃ temperature,the lowest residual COD is obtained at 83.80 mg/L in 5 min.