Influence of tip clearance on heat transfer efficiency in staggered micro-cylinders-group

LIU Zhigang,ZHANG Chengwu,GUAN Ning
DOI: https://doi.org/10.3969/j.issn.0438-1157.2012.04.005
2012-01-01
Abstract:De-ionized water,used as working fluid,flows through a staggered micro-cylinders-group,which is made up of micro-cylinders with hydraulic diameter of 500 μm and height of 500 μm,and an experimental study is performed on the influence of tip clearance on heat transfer efficiency in the staggered micro-cylinders-group.Using an electricity heater,the flow rate and the temperature difference between the inlet and the outlet of micro-cylinders-group are measured and the friction factor and Nusselt numbers can be obtained over Reynolds numbers ranging from 8 to 400.The relationship between heat transfer efficiency and Reynolds number is grasped.The experimental results indicate that the tip clearance has a little influence on flow resistance and Nusselt number at low Reynolds number and these influences become apparent with the increase of Reynolds number.The heat transfer efficiency of micro-cylinders-group heat sink increases rapidly with Reynolds number for a start,and it increases slowly with the increase of Reynolds number,even begins to drop with the further increase of Reynolds number.However,the existence of the tip clearance promotes heat transfer efficiency in the micro-cylinders-group heat sink,though it reduces Nusselt number based on the experimental results.
What problem does this paper attempt to address?