Analysis of Electromagnetic Characteristics for Three Gaps Permanent Magnet Contactor

HE Kaihua,RONG Mingzhe,WU Yi,NIU Chunping,PENG Xiang
DOI: https://doi.org/10.3969/j.issn.1001-5531.2012.13.002
2012-01-01
Abstract:According to the analysis of the configuration for three gaps permanent magnet contactor,the magnetic field and electromagnetic force were calculated with the secondary development of Ansys.A mathematical model of dynamic characteristics analysis was established by coupling mechanical,electromagnetic and electric circuit equations in the closing process of permanent magnet contactor,to calculate its contact bounce and dynamic characteristics.The comparative analysis of the test and calculation results of LC1D32 contactor verify the proposed method.
What problem does this paper attempt to address?