Treatment of Wastewater from Scale Inhibitor Production by Combined Process

Jing-guo CAO,Ping GU,Yang JIANG,Qian LIU,Hai-yan WANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2010.11.031
2010-01-01
Abstract:Due to poor biodegradability,complex components,high amount of total phosphorus and salt,and inorganic polyphosphate and organic phosphonate being the main components of total phosphorus,the wastewater from scale inhibitor production is difficult to be treated.Therefore,a combined process of anaerobic hydrolysis acidification,chemical phosphorus removal by CaO,aerobic biological oxidation and advanced phosphorus removal by flocculant was used to treat the wastewater.The results show that COD,TP and NH3-N concentrations in the effluent are 174.8 mg/L,0.48 mg/L and 0.48 mg/L respectively,attaining the third level criteria specified in Integrated Wastewater Discharge Standard(DB 12/356-2008).
What problem does this paper attempt to address?