Optimization of the key parameters of bolus-tracking technique in CT angiography of upper abdomen

LONG Xue-ying,CAO Jue,PENG Guang-chun,LIU Hui,CHEN Wei,ZHU Zhi-ming,HU Ping
DOI: https://doi.org/10.3969/j.issn.1006-9011.2008.06.027
2008-01-01
Journal of Medical Imaging
Abstract:Objective:To investigate the optimal key parameters of bolus-tracking technique in CT angiography of upper abdomen.Methods:Series of single-level dynamic enhanced CT scanning of upper abdomen were performed among 47 patients,the time-density curves of aortic enhancement of each patient were obtained and the shapes of the curves were analyzed.The peak aortic enhancement and the time to reach the peak enhancement for each patient were obtained,and the optimal aortic enhancement phases were defined.The patients that could be scanned within the optimal aortic enhancement phases using different time points were counted,and the time points that maximum patients could be scanned within the optimal aortic enhancement phases were selected as the optimal fixed delay time;by different enhancement thresholds and different transit delays simulating that were selected in bolus-tracking technique,a total of 84 combinations were selected,and each combination was analyzed according to the time-density curve of aortic enhancement of each patient,the patients that could be scanned within the optimal aortic enhancement phases of each combination were counted,and the optimal combinations were selected if maximum patients could be scanned within the optimal aortic enhancement phases.The proportion of patients that could be scanned within the optimal aortic enhancement phases using two methods(optimal fixed delays and simulated bolus-tracking technique with optimal combinations) was compared.Results:Mean peak aortic enhancement was 228.1±36.7 HU with a mean time of 34.2±4.7 s to reach the peak;the optimal aortic enhancement phase started at a mean time point of 21.8±4.9 s and ended at a mean time point of 40.7±3.7 s with a mean temporal width of 19.2±2.9 s;74.5%(35/47) of the patients could be scanned within the optimal enhancement phases of aorta at an optimal fixed delays of 26 s or 27 s,while 97.9%(46/47) at simulated bolus-tracking technique with the optimal combinations of threshold of 100 HU and transit time of 8 s,there were statistically significant difference(P<0.005) between them.Conclusion:For CT angiography of upper abdomen,adopting bolus-tracking technique may make more patients be scanned within their optimal aortic enhancement phases than using fixed delays;the optimal enhancement threshold and transit delay combinations in bolus-tracking technique seemed to be 100HU and 8 s in this injection protocol.
What problem does this paper attempt to address?