Numerical Si mulation of Smoke Pervasion in Tunnel Fire Affected by Ceiling Flue

Long Xin-feng,Li Yan-ling,Liang Ping
DOI: https://doi.org/10.3321/j.issn:1000-565X.2009.04.020
2009-01-01
Abstract:In order to reveal the effect of a tunnel with ceiling flues on personnel evacuation in fire,the software of Fire Dynamics Simulator(FDS) is used to simulate a medium-scale fire with a heat release rate of 20 MW.The smoke pervasion and temperature distribution varying with the flue-outlet exhaust velocity and the flue setting are then analyzed in detail.The results show that(1) the setting of ceiling flues improves the smoke density in the tunnel from 40 mg/m3 to 120 mg/m3 inside the flue outlet and to 100 mg/m3 outside the outlet;(2) the exhaust at smoke outlets accelerates the moving of smoke from the tunnel into the flue,and greatly reduces the smoke density and temperature outside the two flue outlets near the fire source,thus increasing the safety coefficient for personnel evacuation;(3) at an exhaust velocity of 2.5 m/s,the volume fraction of CO outside the flue outlet approximates to a constant less than 13×10-6 after 300 s,which offers a relatively safe space for personnel evacuation and fire rescue from both the upstream and the downstream;and(4) for the tunnel with ceiling flues,only two flues can be unlocked when a fire occurs.
What problem does this paper attempt to address?