Determination of ecabet in human plasma by high-performance liquid chromatography-tandem mass spectrometry.

Dan Zhang,Xiaolin Du,Mingyuan Liu,Hao Li,Yao Jiang,Limei Zhao,Jingkai Gu
DOI: https://doi.org/10.1016/j.jchromb.2008.01.013
IF: 3.318
2008-01-01
Journal of Chromatography B
Abstract:This paper describes a simple, robust and cost-effective assay for the determination of ecabet in human plasma. After a simple step of protein precipitation using methanol, plasma samples were analyzed by reverse phase high-performance liquid chromatography–electrospray ionization–tandem mass spectrometry (HPLC–ESI–MS/MS) with valsartan as the internal standard (I.S.). Ecabet and the I.S. valsartan were separated on a Venusil MP C18 analytical column using methanol–10mM ammonium acetate (75:25, v/v, pH 3.0) as mobile phase at a flow rate of 1.0mL/min. Ecabet and I.S. were eluted at 0.91 and 0.92min, respectively, ionized in negative mode, and then detected by multiple reaction monitoring (MRM) essay. The MRM transitions of m/z 379.1→m/z 277.1 and m/z 434.3→m/z 350.1 were used to quantify ecabet and I.S., respectively. The assay was linear over the concentration range of 10–6000ng/mL and was successfully applied to a pharmacokinetic study in healthy volunteers.
What problem does this paper attempt to address?