Evolution of Ultrasonic Image of Rabbit Muscle Caused by High Intensity Focused Ultrasound

JIANG Li-xin,HU Bing,WU Rong
DOI: https://doi.org/10.3969/j.issn.1000-3630.2005.04.009
2005-01-01
Abstract:To study evolution of ultrasonic images of rabbit skeletal muscle on legs radiated by high intensity focused ultrasound.Thermal ablation with HIFU was applied to muscles of 20 cases of rabbits transcutaneously.Sonication was examined by twodimensional ultrasound,color Doppler ultrasound and power Doppler ulrtasound respectively before treatments and on the 1d,3d,7d,14d,21d,28d after treatments in 18 rabbits.Two cases of rabbits were anatomized.The sonications were examined histologically.(1)The hyperecho zone around the coagulation necrosis lesions turned into hypoecho zone from 1 day to 7 days after treatments.(2)One day after the treatments,the volume of the ablatin reached the largest.From 3 days to 21 days after the treatments,the volume decreased gradually,until 28 days after the treatments when the volume became the smallest.Ultrasound examination is useful in the followup inspection after HIFU.It will provide a valuable basis for studying ultrasonic image evolution of soft tissue tumor treated by HIFU further.
What problem does this paper attempt to address?