Oversulfated Chondroitin Sulfate: Impact of a Heparin Impurity, Associated with Adverse Clinical Events, on Low-Molecular-Weight Heparin Preparation

Zhenqing Zhang,Michel Weiwer,Boyangzi Li,Melissa M. Kemp,Tyler H. Daman,Robert J. Linhardt
DOI: https://doi.org/10.1021/jm800785t
IF: 8.039
2008-01-01
Journal of Medicinal Chemistry
Abstract:Heparin, a widely used anticoagulant, is being rapidly displaced by low-molecular-weight heparins. Recently, certain lots of heparin have been associated with anaphylactoid-type reactions resulting from contamination with oversulfated chondroitin sulfate. This impurity has also contaminated low-molecular-weight heparins obtained by chemical and enzymatic depolymerization of heparin. The sensitivity of oversulfated chondroitin sulfate to five different depolymerization processes similar to ones used in preparing low-molecular-weight heparins is reported.