Application Value of Multi-Slice Helical CT in Post Processing Original Image Technique to Bone Trauma
黄小华,张小明,董国礼,翟昭华,敬宗林,李春平,罗开
DOI: https://doi.org/10.3969/j.issn.1006-9011.2005.04.014
2005-01-01
Journal of Medical Imaging
Abstract:Objective:To evaluate the application value of multi-slice helical CT with two or three-dimensional imaging reconstruction in bone trauma.Methods:All of 60 cases of bone trauma were examined by X-ray plain film. Afterwards, all cases were scanned with 16-slice helical CT again.All raw data were transferred to workstation and processed for 2D/3D imaging reconstruction.Results:Each of 60 cases of bone trauma had fracture, 35 cases of which were confirmed with X-ray plain film, 41 cases with CT plain scan,56 cases with two or three-dimensional image,59 cases with CT plain scan and two or three-dimensional image together. There was not significantly different (P0.05)for the cases between X-ray plain film and CT plain scan in determining bone fractures by χ 2-test. However, There was significantly different (P0.01)for the ones between 2D/3D imaging reconstruction or it and CT plain scan together and X-ray plain film or CT plain scan.Conclusion:It could display clearly the anatomic structure of bone, and determine fractures and fractured types by the techniques of processing original image. Two or three-dimensional reconstruction imaging of bone was important complement to CT plain scan, both of them had important value to diagnose bone trauma.