Clinical Evaluation of Multi-slice Spiral CT Postprocessing in the Diagnosis of Bone Tumors

李慎江,李惠民,肖湘生,刘士远,李成洲,贾宁阳
DOI: https://doi.org/10.3969/j.issn.1001-9324.2003.05.015
2003-01-01
Abstract:Objective To clinically evaluate multi slice spiral CT (MSCT) postprocessing in diagnosing bone tumors.Materials and Methods MSCT scanning was performed in 34 patients with bone tumors. Based on the raw data, four kinds of image reconstruction, including multiple planar reconstruction (MPR), maximum intensity projection (MIP), 3 dimensional reconstruction (3D) and 4 dimensional reconstruction (4D), were carried out. The diagnostic value of each of four reconstructed images was assessed and compared with each other.Results The lesions were well shown on all kinds of reconstructed images. MPR accurately displayed the lesion's extent and minute structures, while MIP and 3D stereoscopically showed the bony changes. And 4D stereoscopically demonstrated not only bony changes but also lesion's extent and minute structures. Combined with axial images, the above four reconstructed images could display the tumor's extent, bony changes and the shape of periosteal reaction from different angles.Conclusion All the four kinds of MSCT postprocessing images can fully and accurately demonstrate the bone tumor, combined with the axial images correct evaluation of the bone tumor can be made.