Treatment of Highly Concentrated Industrial Wastewater with Salt and COD by Double-pass Membrane Process at High Tempreture

Li Xiaodan,Zhang Shouhai,Han Runlin,Zhao Weiying,Jian Xigao
DOI: https://doi.org/10.3969/j.issn.1002-154X.2009.06.002
2009-01-01
Abstract:The flat plate RO testing device was used to evaluate the treatment efficiency of the industrial waste water discharged by a chemical plant in Dalian.Poly(phthalazine ether sulfone ketone)(PPESK) UF was adopted and tested as a supporting layer which was used to prepare for the polyamide RO membrane by the method of interfacial polymerization.The effects of operating parameters on the performance of the process were investigated.The study shows that the overall conductivity and COD of the feed water were effectively removed at 60 ℃ after a double-pass reverse osmosis process.Furthermore,the rejection of the overall conductivity and COD were stabilized at about 93% and 98.3% respectively.High removal efficiency was observed during long term research,which demonstrated good thermal stability.