Radiochromic film in the dosimetric verification of intensity modulated radiation therapy

ZHOU Ying-juan,HUANG Shao-min,DENG Xiao-wu
DOI: https://doi.org/10.3760/j.issn:1004-4221.2007.04.016
2007-01-01
Abstract:Objective Objective To investigate the dose-response behavior of a new type of radio- chromic film(GAFCHROMIC~(?) EBT) and explore the clinical application means and precision of dosage measurement, which can be applied for: (1) plan-specific dosimetric verification for intensity modulated ra- diation therapy, (2) to simplify the process of quality assurance using traditional radiographic film dosimet- ric system and (3) to establish a more reliable, more efficient dosimetric verification system for intensity modulated radiation therapy. Methods (1) The step wedge calibration technique was used to calibrate EBT radiochromic film and EDR2 radiographic film. The dose characteristics, the measurement consistency and the quality assurance process between the two methods were compared. (2) The in-phantom dose-meas- urement based verification technique has been adopted. Respectively, EBT film and EDR2 film were used to measure the same dose plane of IMRT treatment plans. The results of the dose map, dose profiles and iso- dose curves were compared with those calculated by CORVUS treatment planning system to evaluate the func- tion of EBT film for dosimetric verification for intensity modulated radiation therapy. Results (1) Over the external beam dosimetric range of 0-500 cGy, EBT/VXR-16 and EDR2/VXR-16 film dosimetric system had the same measurement consistency with the measurement variability less then 0.70%. The mean meas- urement variability of these two systems was 0.37% and 0.68%, respectively. The former proved to be the superior modality at measurement consistency, reliability, and efficiency over dynamic clinical dose range, furthermore, its quality assurance showed less process than the latter. (2) The dosimetric verification of IM- RT plane measured with EBT film was quite similar to that with EDR2 film which was processed under strict quality control. In a plane of the phantom, the maximal dose deviation off axis between EBT film measure ment and the TPS calculation was 3.1%, and for EDR2 film the deviation was 3.6%. With the same de- fined value of DTA and AD, the conformity of pixels meeting the test criteria between the plan and measure- ment was 94.28% and 92.92% for EBT and EDR2 film, respectively. Conclusion EBT radiochromic film based radiation dosimetric system can be applied simply with less quality control process. When com- pared with the radiographic film, the EBT film dosimetric system is more feasible and more reliable for plan- specific dosimetric verification for intensity modulated radiation therapy, which can be extended in chnical application.
What problem does this paper attempt to address?