Reliability Analysis on Ballast Water Treatment by Combination of Micro-Pore Filtration and UV Radiation

刘胜杰,张曼霞,王亚童,朱益民
DOI: https://doi.org/10.3969/j.issn.1007-6336.2010.03.031
2010-01-01
Abstract:The treatment of simulated ballast water which mixes with chlorella,Nitzschia closterum and Platymonas subcordiformis was conducted.Using the combination of micro-pore filtration and UV radiation,the removal rate of algae and the pressure loss of filtration were studied experimentally,and the optimal flow rate and the reliability of the treatment device were discussed.The results show that the removal rate of algae is up to 84.4%,and the inactivation rate on oceanic bacteria was above 80%.The removal rate is higher for the larger size of algae.The pressure loss was increased with an increase of the treated water volume.The max flow rate is 10m3/h,and the optimal flow rate is 5m3/h for the device.The capable volume of continuous treatment is 100m3,and the continuous treatment period is 20h.