Establishment and performance of the O3/UV pilot-scale ballast water treatment

Zhong XU,Guozhen CHEN,Ting SU,Siyuan ZHANG,Hong YOU
DOI: https://doi.org/10.11918/j.issn.0367-6234.201608031
2018-01-01
Abstract:To explore the treatment method that enables the quality of ballast water to meet the discharge standard, the O3/UV combined ballast water treatment system was established, in which O3 and UV can be controlled independently. Escherichia coli and Dunaliellasalina are target microorganisms. To study the system performance in inactivating microorganisms, MPN and CFDA-AM fluorescence staining were used to count residual viable bacteria and residual viable algae respectively. N, N-Diethyl-p-phenylenediamine ( DPD) spectrophotometry was used to measure the attenuation of total residual oxide ( TRO) generated in the system. The results show that O3 and UV have a synergistic effect, and the combination of the two has better performance of inactivation than that of the individual treatment. Under the condition of 67μW/cm2 UV irradiance, 1.62 g/h of the O3 dosage for 1s exposure, the Escherichia coli and Dunaliellasalinacan cannot be detected after 2 h, which means the effluent can meet IMO microbial inactivation standards. TRO concentration decayed with time, and the experiment did not detect the resurrection of bacteria and algae, which indicate a good continuous inactivation performance of the system. Compared with individual treatment, the combined system increases the treatment efficiency and reduces the energy consumption, which makes itself a promising method.
What problem does this paper attempt to address?