Effect of an applied electric field on the clogging of continuous casting nozzle

SUN Yong,MA Beiyue,YU Jingkun
DOI: https://doi.org/10.13228/j.boyuan.issn1005-4006.2008.06.003
2008-01-01
Abstract:The clogging of continuous casting nozzle has a great effect on the continuous casting, quality of strand and safe production of steel.An electric field was applied on submerged entry nozzle added with ZrO_2 solid electrolyte on the outer layer and the effect of current flow on thickness of de- posit was investigated.The results showed that with the increase of current flow,the thickness of de- posit in the anode decreased correspondingly,however,in the cathode,the thickness of deposit in- creased dramatically.Comparing with the nozzle without an applied electric field,when the current flow was 1 A,the thickness of deposit in the anode decreased by 70%,and increased by 72% in the cathode.Similarly,when the current flow was up to 5A,the thickness of deposit in the anode decreased by 90%,and increased by 156% in the cathode.Taking the inner layer and outer layer as electrode con- nected with current source,the clogging and erosion of the nozzle could be prevented simultaneously.
What problem does this paper attempt to address?