Comparing radiation treatments using intensity-modulated beams, multiple arcs, and single arcs.
Grace Tang,Matthew A Earl,Shuang Luan,Chao Wang,Majid M Mohiuddin,Cedric X Yu
DOI: https://doi.org/10.1016/j.ijrobp.2009.04.003
IF: 8.013
2010-01-01
International Journal of Radiation Oncology*Biology*Physics
Abstract:A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings.Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient.Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases.IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.