Determination of blood glucose based on a fluorescence reaction system of glucose oxidase-horseradish peroxidase-glucose-guaiacol

LI Yong-sheng
2011-01-01
Abstract:By using the fluorescence characteristics of guaiacol(λex/λem=280/610nm),a fluorescence quenching reaction system of glucose/glucose oxidase/horseradish peroxidase was proposed.And then the system was combined with the fluorescence capillary analysis,a novel method for determination of trace-level serum glucose was developed(LE-GFCA).The optimized conditions for the determination were as follows: the reaction time was 15 min,the reaction temperature was 30℃,the active concentrations of HRP and GOD were 4500U/L and 2500U/L,respectively,the concentration of guaiacol was 150 μmol/L,the buffer used was phosphate solution(pH 7.5).In this method,its linear range was 10~160 μmol/L,relative standard deviation was less than 2.3%,the detection limits were in the range of 1.2~5.4 μmol/L,the recoveries were in the range of 96.8%~103.7%.The actual human serum was determined,and results of the LE-GFCA method were consistent with those obtained by glucose-kit method.
What problem does this paper attempt to address?