Study and Countermeasure on Side Effects from Principal Stress Axis Rotation Experiment with Hollow Cylinder Apparatus

周建,沈扬,郑伟
DOI: https://doi.org/10.3969/j.issn.1000-0860.2005.11.010
2005-01-01
Abstract:Some problems from the principal stress axis rotation experiment with hollow cylinder apparatus are analyzed in detail herein;which consists of three aspects,such as the preparation of the hollow cylinder sample and the acquisition of the isotropic one;the estimation and elimination of the size effect and the end effect in the experiment;and the membrane penetration effect on both the drained and the undrained tests results,etc.The relevant countermeasures are put forward based on the systematic study concerned,and then some beneficial recommendations for obtaining and modifying the reasonable test results are presented as well.