Abstract:Removal of simulated isobutyl acetate(IA) gas was investigated via dielectric barrier discharge(DBD) technology.The results showed that when the gas flow rate was 1.8 m /s and the initial IA mass concentration was 1788 mg /m3,the removal efficiency of IA reached 75.3% at 9.0 kV of applied voltage.The removal efficiency of IA increased with increasing applied voltage and decreasing initial concentration and gas flow rate.The discharge gap could also influence the IA waste gas removal efficiency via DBD technology.The energy yield had a non-linear correlation with gas flow rate.To obtain high energy yield,applied voltage should be controlled at 7.5 and 9.0 kV.We also investigated the removal efficiency,treatment cost and feasibility of decomposition of actual industrial waste gas containing IA.The results showed that removal efficiency of IA was above 80% when applied voltage,gas flux,and gas flow rate in the DBD reactor region were set at 16 kV,2000 m3 /h,and 5.4 m /s,respectively.The treatment cost of IA was approximately 0.012 yuan /m3.Lastly,the likely reaction pathways for the removal of IA by DBD were discussed on the basis of byproducts analysis.