Determination of Phosethyl-Al and the Impurities by Ion-exchange Chromatography

王雪,朱岩,张嘉捷
DOI: https://doi.org/10.3785/j.issn.1008-9497.2009.02.015
2009-01-01
Abstract:An ion chromatography method with non-suppressed conductivity detection was developed for simultaneous determination of phosethyl-Al and the impurities in it . High capacity column AS9-HC was chosen, and the eluent was 9mmol·L-1 Na2CO3. 0.02 mol·L-1H2SO4 was used as suppressing solution. The limit of detection(S/N=3)of phosethyl-Al, chloride, phosphite, sodium, phosphate were 15, 3, 12, 6, 5μg·L-1, respectively. The relative standard deviations (RSDs) of retention time, peak area and peak height of phosethyl-Al were 0.30%, 1.31% and 0.13%.The recovery of phosephy-Al was 91%.The result was satisfactory, and the method was proised to be suitable for the determination and quality control of phosethyl-Al product.
What problem does this paper attempt to address?