Static and Fatigue Experimental Study on Crack Width of Interior Prestressed Composite Beams

An ZHOU,Hang DAI,Qi-wei LIU
DOI: https://doi.org/10.3969/j.issn.1002-0268.2007.10.018
2007-01-01
Journal of Highway and Transportation Research and Development
Abstract:Seven simple supported steel-concrete composite beams,in which the flanges proportioned with pre-stressing tendons,are tested for static and fatigue analysis.The test specimens were designed with different pre-stressing degrees,different stud spacings,and the steel fibre ratios inside concrete flanges are 0%,0.8% and 1.5% respectively.Static result shows that the crack distributions at ultimate status are similar and the average crack width is about 80~110 mm for different situations.From the result analysis,it was found that the prestressing-degree,fiber-ratio,force-ratio,connection-degree,reinforcement-ratio and shear stud spacing,etc.would affect the width of the crack.Considering such factors,an equation is proposed for calculation of the maximum crack width.The relationship between the concrete crack width and the fatigue damage with the loading cycles are tested and recorded using dynamic coefficient method.Test result shows that SFRC prestressed composite beam with crack development inside the concrete is working steady under fatigue load and the damage degree increased only 20% after 1.8 million loading cycles.
What problem does this paper attempt to address?