Comparison of digital rectal examination,guided prostate biopsy,magnetic resonance imaging and diffusion weighted imaging in localization of prostate cancer with whole-mount step section pathology

ZHANG Fan,HUANG Yi,GAO Baoxiang,LU Min,WANG Guoliang,MA Lulin
DOI: https://doi.org/10.13201/j.issn.1001-1420.2012.03.016
2012-01-01
Journal of Clinical Urology
Abstract:Objective:To evaluate the accuracy of digital rectal examination,transrectal ultrosound-guided biopsy,magnetic resonance imaging and diffusion weighted imaging in localization of prostate cancer with the whole-mount step section pathology.Method:There are 19 patients treated by laparoscopic radical prostatectomy between Oct.2009 and Mar.2010.With the exclusion of absence of MRI/DWI examination,surgery history of prostate and previous hormonal therapy,10 patients were included finally.We collected the information of DRE,TRUS-guided biopsy,MRI and DWI before the radical prostatectomy and made the whole mount step section pathology after surgery.We divided the prostatic gland into sextants,followed by using DRE to locate the nodules,doing 12 TRUS-guided biopsies and numbering them,putting the positive ones into the right sextants.Two doctors read the MRI/DWI without knowing the patients' information and scored for each sextant.There were 5 point-scales,that was: 1-definitely no cancer,2-probably no cancer,3-possible cancer,4-probable cancer and 5-definite cancer.When the average score=4,we assumed that sextant was evaluated as the prostate cancer region by MRI or MRI/DWI.Result:In 10 patients with 60 sextants,there were 27(45%) prostate cancer sextants approved by whole-mount step section pathologic.The number of prostate cancer sextant was 8(40%),11(55%) and 8(40%) in base,mid and apex part respectively.The sensitivity and specificity of DRE was 29.6% and 72.7%,lower than the other methods.The sensitivity and specificity of the TRUB-guided biopsy localized diagnosis was 55.6% and 81.8%,similar with MRI(51.9% and 84.9%).When considered DWI,the specificity was the same while the sensitivity elevated to 77.8%.As for the apex and mid parts,the sensitivities of MRI were a little bit low(37.5% and 45.5%),but the specificities and positive predictive value were high(100% and 100%).And the sensitivities of MRI for the apex and mid parts were elevate to 75% and 81.8% respectively when DWI was involved.Conclusion:The value of MRI in diagnosing prostate cancer have accuracy similar to TRUB-guided biopsy and better than DRE,the combination of MRI and DWI can elevate the sensitivity of MRI for localized diagnosis in prostate cancer,especially in apex and mid parts of the prostate.
What problem does this paper attempt to address?